Container Technical Specifications and Datasheet
All the technical details of our standard container – from the weld-free galvanised frame to panel insulation, from door sizes to the electrical installation. All materials are TSE certified.
A rust-resistant, weld-free, insulated module
In brief
Our containers are made with a bolted load-bearing frame produced from galvanised / galvalume sheet by laser cutting and press-brake bending, 50 mm polyurethane-insulated sandwich wall panels, a 40 mm polyurethane-insulated corrugated roof panel and a PVC floor on 14 mm fibre cement. They are designed for 80 kg/m² snow and 102 km/h wind, and come with a 2-year warranty.
Why weld-free galvanised steel?
Our standard production uses no black steel, cold-rolled (DKP) sheet or welding. Welding burns and damages the galvanised coating; because we do not weld, the coating stays intact and the frame is protected against corrosion. Bolted connections also make it easier to dismantle and reinstall the modules.
Two standard module sizes
Modules are joined side by side to create larger spaces; custom sizes are assessed per project.
2.40 × 5.98 m module
- External dimensions
- 2.40 × 5.98 × 2.50 m
- Area
- approx. 14.4 m²
- Empty weight
- approx. 1150 kg
- Clear internal height
- 2280 mm
3.00 × 7.00 m module
- External dimensions
- 3.00 × 7.00 × 2.50 m
- Area
- 21 m²
- Empty weight
- approx. 1450 kg
- Clear internal height
- 2280 mm
Load, insulation and earthquake values
| Property | Value | Reference / note |
|---|---|---|
| Snow load | 80 kg/m² | TS 498 · TS EN 1991-1-3 |
| Wind speed | 102 km/h (50 kg/m²) | TS 498 · TS EN 1991-1-4 |
| Chassis load capacity | 200 kg/m² | TS 498 |
| External wall U-value | 0.72 W/m²K (0.62 kcal/m²h°C) | 50 mm PUR panel |
| Internal wall U-value | 0.68 W/m²K (0.58 kcal/m²h°C) | 50 mm PUR panel |
| Roof U-value | 0.55 W/m²K (0.47 kcal/m²h°C) | 40 mm PUR roof panel |
| Floor U-value | 4 W/m²K (2.97 kcal/m²h°C) | 14 mm fibre cement |
| Earthquake | Calculated for the installation site | PGA, Ss, S1 acceleration coefficients · importance factor I = 1 · live load participation factor n = 0.3 |
| Climate zone | Walls suitable for climate zone 1 | TS 825 (Turkish standard) · roof close to the zone 1 value |
Section-by-section technical specification
The materials and dimensions used in our standard container. For custom projects, changes are stated in the specification attached to the quotation.
Load-bearing frame and chassis
Weld-free construction technology: bolted system made of galvanised structural steel.
- Construction system
- Weld-free construction technology; bolted container system
- Material
- Galvanised / galvalume steel sheet (DX51D+Z / DX51D+AZ). No black steel, cold-rolled (DKP) sheet or welding is used in standard production.
- Manufacturing
- Top chassis, bottom chassis frame profiles, corner profiles and C-section support profiles, shaped by laser cutting and press-brake bending
- Custom projects
- Based on static calculations, profile wall thickness and width are increased and the number of C-section supports is multiplied; where needed, column-beam reinforcement with structural steel sections is added
External and internal walls
50 mm polyurethane-insulated sandwich panels with pre-painted galvanised steel faces.
- External walls
- 50 mm sandwich wall panel
- Panel insulation
- Approx. 50 mm polyurethane (PUR), fire class B1, 30–32 kg/m³
- Panel faces
- 0.25–0.30 mm (TS EN 10143 ±0.04 mm) coil-coated pre-painted galvanised / galvalume steel, S-type profiled sheet
- Internal walls
- 50 mm sandwich wall panel, internal wall height 2280 mm
- Height
- Total external height 2500 mm (including 65 mm lifting-lug projection) · clear internal height 2280 mm · 2000 mm in squat-toilet sections
Roof and ceiling
40 mm polyurethane-insulated corrugated sandwich roof panel.
- Structure
- Special (50+50)×140 mm cold-formed frame profile (galvanised DX51D+Z / galvalume DX51D+AZ), roof panels and three C-section support profiles on top
- Roof covering
- 40 mm thick, 3-rib corrugated sandwich roof panel
- External face
- 0.40 mm coil-coated pre-painted galvanised / galvalume trapezoidal sheet, rib depth 34 mm
- Insulation
- Approx. 40 mm polyurethane, fire class B1, 36 kg/m³
- Ceiling
- 0.30 mm coil-coated pre-painted galvanised / galvalume S-type profiled sheet
- Rainwater
- Drained through openings in the top chassis
Floor
Galvanised profile structure, PVC covering on 14 mm fibre cement board.
- Structure
- Special (50+70)×140 mm frame profile and 50×97 mm C-section cold-formed profiles, galvanised / galvalume DX51D+Z / DX51D+AZ
- Covering
- PVC floor covering on 14 mm fibre cement board
- Load capacity
- 200 kg/m² (according to TS 498)
Doors and windows
Insulated steel external door, MDF laminate internal doors, PVC windows with 4+9+4 double glazing.
- External door
- 920×2000×45 mm insulated steel door; EPS core inside RAL 9002 pre-painted galvanised steel skins; 1.0 mm pre-painted steel frame with rubber seals
- Internal door
- 825×1993 mm MDF laminate door, leaf thickness 42 mm
- Wet-area doors
- 620×1993 mm and 720×1993 mm MDF laminate doors; 65×195 cm PVC doors in toilet blocks
- Locks and handles
- Cylinder lock on the external door, mortice or WC locks on internal doors; metal door handles (TSE certified)
- Window
- 970×1200 mm self-framed PVC joinery
- Glazing
- 4+9+4 mm double glazing (TSE certified)
- Ventilation
- 100×100 vents in kitchen, toilet and shower
Paint and colour
RAL 9002 grey white, coil-coated pre-painted galvanised steel.
- External surfaces
- Coil-coated RAL 9002 grey white pre-painted galvanised / galvalume steel
- Door frames
- 1.0 mm RAL 9002 pre-painted or oven-painted galvanised / galvalume steel
- Corner and vertical supports
- RAL 9002
- Other metal parts
- Galvanised / galvalume structure is not painted
Electrical installation
NYM cable, surface-mounted trunking, 30 mA residual current device; all materials TSE certified.
- Capacity
- 2000 W, 220 V, 50 Hz
- Socket circuits
- 3×2.5 mm² NYM cable, surface-mounted cable trunking
- Lighting circuits
- 3×1.5 mm² NYM cable, surface-mounted cable trunking
- Light fittings
- Square fittings in dry areas; IP44 bulkhead lights in wet areas and above the external door
- Sockets and switches
- Surface-mounted
- Circuit breakers
- Miniature circuit breakers, PVC distribution box
- Residual current protection
- 2×40 A, 30 mA single-phase residual current device
- Mains connection
- To a thermoplastic junction box, carried out by the client
Plumbing and sanitary
PPRC clean water, PVC wastewater; acrylic shower tray and squat pan.
- Washbasin
- 28×35 cm wall-mounted
- Taps
- Plumbing suitable for an instantaneous water heater (heater supplied by the customer); shower taps wall-mounted, basin mixers mounted on the basin
- Toilet
- Western type, plastic cistern, with bidet tap
- Squat pan and shower tray
- 92×102 cm, glass-fibre-reinforced acrylic, one-piece
- Kitchen sink
- 50×100 cm stainless steel sink, 100 cm base cabinet with two doors (no wall cabinet)
- Accessories
- PVC toilet roll holder, soap dish, mirror, toilet seat
- Pipes
- PPRC for clean water, PVC for wastewater
Lifting and positioning
Lifted with slings from the lifting plates; placed on a level concrete base or on blocks.
- Lifting
- Loaded and unloaded with equal-length slings locked to the lifting plates on both long sides
- Positioning
- On a level concrete base or on blocks as described in the instructions
- Stacking and joining
- The standard container is designed for single-storey use; with structural changes it can be built multi-storey, and modules can be joined side by side
Standards used in design and calculation
Structural, load, earthquake and thermal insulation calculations are carried out according to the following standards and regulations.
- TS 498
- TS 648
- TS 11372
- TS 6793
- TS 3357
- TS 825
- TS EN 10143
- TS EN 1993-1-1 / 1-2 / 1-8 (Eurocode 3)
- TS EN 1991-1-3 / 1-4 (Eurocode 1)
- TS EN 1998-1 (Eurocode 8)
- Turkish Building Earthquake Code 2018
- Turkish Steel Structures Regulation 2016
- ASCE 7-05 wind and snow
- AISC 360-10 / 360-16 connection design
- Turkish Thermal Insulation Regulation
Quotation scope, delivery and warranty
Warranty and delivery
2 yearsproduct warranty · all materials TSE certified
Shipment begins within 20 working days of contract approval and receipt of payment. Lead times are shorter for models in stock.
Included in the standard quotation
- Door and window joinery
- Insulated double glazing
- Electrical installation materials
- Plumbing materials and installation, where included in the project
- PVC floor covering
- Assembly of combined containers
- Loading onto the transport vehicle at the factory
Planned separately for each project
- Transport, transport insurance and unloading crane
- Preparation of the ground the container will sit on
- Heating and cooling installation and equipment
- Three-phase installation, telephone and data lines, earthing
- External (mains) connections of the installations
For every project, the scope is confirmed in writing with the technical specification and drawings attached to the quotation.
Are your containers welded?
No. Our standard production uses no black steel, cold-rolled (DKP) sheet or welding. The load-bearing frame is built with a bolted (weld-free) system from profiles made of galvanised / galvalume sheet by laser cutting and press-brake bending. This structure is corrosion resistant and very strong.
What are the standard container dimensions?
Our containers are made in standard sizes of 2.40 × 5.98 × 2.50 m and 3.00 × 7.00 × 2.50 m. The clear internal height is 2280 mm.
How much does a container weigh?
The empty weight is approximately 1150 kg for the 2.40 × 5.98 m model and 1450 kg for the 3.00 × 7.00 m model.
How are the walls and roof insulated?
The walls use sandwich panels with approx. 50 mm polyurethane (PUR) insulation, and the roof uses 40 mm polyurethane-insulated corrugated sandwich roof panels. The panels are fire class B1.
How are snow, wind and earthquake loads calculated?
Containers are designed for an 80 kg/m² snow load and 102 km/h wind speed according to TS 498 and TS EN 1991. Earthquake calculations are based on the acceleration values of the installation site, using the Turkish Building Earthquake Code 2018; for projects outside Türkiye, local requirements are reviewed at the quotation stage.
Can containers be stacked?
The standard container is designed for single-storey use. For multi-storey buildings a static calculation is carried out, and the structure is manufactured with increased profile thicknesses and supports.
How long is the warranty?
Our products come with a 2 years warranty. All materials used in manufacturing are TSE certified (Turkish Standards Institution).
What is the delivery time?
Shipment begins within 20 working days of contract approval and receipt of payment. Lead times are shorter for models in stock.
Do you deliver outside Türkiye?
Yes. Containers are shipped from our factory in Kocaeli, either fully assembled (monoblock) or as flat packs that take up much less space in transport. Shipping, insurance, delivery terms and on-site installation scope are set out in the quotation.
Let’s adapt the specification to your project
Send us your plan or list of requirements – we will prepare our written quotation together with the technical specification and drawings.